The ideal solution for industrial radiation processing applications. For use with B3 radiochromic, FWT radiochromic, GAF film CTA film, and Harwell PMMA dosimeters. Dose range 1-150 kGy for B3, 1-100 kGy for FWT, 1-55 kGy for Amber/Red Perspex PMMA, 10-300 kGy for CTA. Use outside these dose ranges may be possible.
The DoseControl® dosimetry system integrates a powerful FDA 21CFR Part 11 conforming dosimetry software with a Thermo Scientific spectrophotometer, controlling the measurement process and making it simple to create and maintain dosimetry records. This system is a versatile solution for industrial routine dosimetry applications. Simply integrates with other systems (ERP, MES, QMS, SAP, Netsuite, PeopleSoft, etc.).
description DOWNLOAD → DoseControl Dosimetry System Brochure PDF
DoseControl-Evolution Dosimetry System - DEMO VIDEO
DoseControl-GENESYS30 Dosimetry System - DEMO VIDEO
Makes operations efficient and audits easy.
Uniformity of measurements
Software controls spectrophotometer.
Specialized holders ensure consistent dosimeter placement.
Every measurement follows the same process.
Eliminates user error.
Fast and reliable.
Powerful Dosimetry Software
Provides step-by-step management of the dosimetry workflow.
Designed to meet the needs of industrial dosimetry.
FDA 21 CFR part 11 compliant.
Controlled user access and permissions.
Complete audit trail.
Simple integration with other systems (SAP, NetSuite, EPR, QMS).
Secure PDF reports.
More details about DoseControl software.
Ensures Measurement Integrity
B3 dosimeter measurements linked simultaneously to scanned barcode ID number.
Absorbance and thickness of Red and Amber Perspex are linked because they are measured simultaneously in the same holder.
Quick, controlled, traceable dose measurements.
The DoseControl® dosimetry system scans the dosimeter ID at the time of measurement, assuring the dose is traceable to a specific dosimeter.
1. Easy to Use
-
Simply place the dosimeter in the holder and press the "Measure" button.
-
The system automatically captures all the information related to the measurement.
-
DoseControl prompts the user through each step.
2. Controlled Measurement Process
DoseControl enforces a consistent measurement routine for each user.
-
Configure measurement and process parameters in advance, and then lock in this process in place for other users.
-
Limit the number of re-reads (re-measurement of dosimeters), and enforce specific reasons and methods for re-reads.
-
Reduces user error and minimizes risk.
3. Permanent Record of Measurement Data
DoseControl captures all information related to the process, dosimeter measurements, user logins, dates/time. This information cannot be deleted or removed. Any changes are recorded.
-
Dosimeter absorbance
-
Dose calculation
-
Dosimeter ID
-
Who made the measurement - User ID
-
Date/time of the measurement
-
Measurement metadata - the calibration, the spectrophotometer S/N, the dosimeter batch, the irradiation pathway.
-
All activities - any re-measurements, any comments, any changes.
-
Any process parameters - as defined by you.
Your choice of Spectrophotometer
Powerful and flexible software to create and maintain FDA 21 CFR Part 11 compliant dosimetry records.
B3, FWT, CTA and Perspex dosimeters
Thermo Scientific Evolution Spectrophotometer
High performance, state-of-the-art spectrophotometer, with specialized dosimeter holders and internal barcode reader. Ideal for high volume dosimetry users. Excellent choice for users that want on-site serviceability.
-
Performance verification (P.V.) Module in DoseControl - automated daily P.V. checks of instrument with audit trail and PDF reports.
-
You can leave the lid open during measurements. The dosimeter holder system is designed to block stray light.
-
Long-life xenon lamp, which means limited downtime. (3 year guarantee, average life 5 years with 24/7/365 operation.) No changing the lamp. Done by Thermo technician.
-
No instrument warm up time. You can begin measurements after a 3 minute initialization from a cold start.
-
Comprehensive calibration and performance verification capabilities - empowers you to do this yourself without needing to call a tech or send the unit to Thermo. Re-calibrate the wavelength using the internal Xenon lamp, a Mercury Lamp accessory, or automated CVC accessory. Use the Thermo INSIGHT for complete performance verification testing.
B3 and FWT dosimeters
Thermo Scientific GENESYS 30 Spectrophotometer
High quality spectrophotometer with specialized dosimeter holders and internal barcode scanner. Next generation instrument for dosimetry, replacing the Genesys 20 model. Stable and durable, the GENESYS 30 is an ideal, high-performing instrument for dosimetry.
-
You can leave the lid open during measurements. The dosimeter holder system is designed to block stray light.
-
Simplified lamp change process. Lamp is pre-aligned and you simply insert it into place.
-
Tungsten-halogen lamp rated at 1000 hours of use.
Need more information?
Brochure: DoseControl System
Details about spectrophotometers, dosimeter holders, hardware and software.
Download PDF...Demo Video Library
Take a look at demonstration videos about using DoseControl.